Copper Bonded Lightning Arrestor Rod

      Description


      Copper Bonded Lightning Arrestor Rod

      Safeguard Your Assets with Superior Lightning Protection

      In an age where technological dependency is paramount and structural integrity is non-negotiable, reliable lightning protection is more crucial than ever. Our Copper Bonded Lightning Arrestor Rods are engineered to provide an unparalleled first line of defense against the destructive forces of lightning strikes, ensuring the safety of personnel, the longevity of structures, and the continuous operation of critical equipment.

      By effectively intercepting direct lightning strikes and safely dissipating the immense electrical energy into the grounding system, our arrestor rods stand as an essential component of any comprehensive lightning protection and earthing solution.

      Key Features

      • Superior Conductivity: Featuring a thick, molecularly bonded layer of high-purity electrolytic copper (typically 250 microns or greater) over a high-tensile steel core, our rods offer exceptional electrical conductivity, ensuring rapid and efficient discharge of lightning current.
      • High-Strength Steel Core: The robust steel core provides immense tensile strength, allowing the rod to withstand significant mechanical stress, bending, and harsh environmental conditions without compromising structural integrity.
      • Corrosion Resistance: The copper bonding offers outstanding resistance to oxidation and corrosion, significantly extending the service life of the rod, even in highly aggressive soil or atmospheric environments. This outlasts traditional galvanized steel options by decades.
      • Permanent Molecular Bond: Manufactured using an electrolytic process, the copper is permanently bonded to the steel core, ensuring the copper layer will not crack, peel, or separate, even under extreme conditions.
      • Optimized Design: Each rod is precision-machined with a sharpened or pointed tip to effectively attract and capture lightning discharges, directing them safely away from your structure.
      • Cost-Effective Solution: Offers the conductivity and corrosion resistance comparable to solid copper rods at a fraction of the cost, providing superior value and performance.
      • Standards Compliance: Manufactured to meet or exceed international standards such as UL 467, IEC 62561-2, IEEE, NFPA 780, ensuring reliability and universal compatibility.

      Benefits

      • Unrivaled Asset Protection: Prevents catastrophic damage to buildings, electronic equipment, machinery, and sensitive instruments from direct lightning strikes.
      • Enhanced Safety: Protects personnel within and around structures from direct and indirect lightning effects.
      • Reduced Downtime: Minimizes operational interruptions and costly repairs associated with lightning-induced failures.
      • Long-Term Durability: Enjoy decades of maintenance-free service thanks to the robust construction and superior corrosion resistance.
      • Peace of Mind: Invest in a proven, high-performance solution that offers reliable protection against one of nature's most unpredictable forces.
      • Easy Integration: Designed for seamless integration into new or existing lightning protection and earthing systems.

      Applications

      Our Copper Bonded Lightning Arrestor Rods are versatile and indispensable for a wide range of applications, including:

      • Residential Buildings: Homes, apartments, and condominiums.
      • Commercial & Industrial Facilities: Factories, warehouses, office complexes, shopping centers, data centers.
      • Telecommunication Towers: Cellular, radio, and broadcasting towers.
      • Power Generation & Distribution: Substations, power plants, transmission towers.
      • Infrastructure: Bridges, tunnels, airports, railway systems.
      • Oil & Gas Facilities: Refineries, storage tanks, pipelines.
      • Critical Infrastructure: Hospitals, emergency services, government buildings.

      Technical Specifications

      FeatureDetail
      MaterialHigh-tensile steel core, molecularly bonded with electrolytic copper
      Copper ThicknessTypically 250 microns (0.25mm) or greater, conforming to international standards
      Diameter Range12mm, 14mm, 16mm, 19mm, 25mm (other sizes available upon request)
      Length Range1.5 meters, 2 meters, 2.5 meters, 3 meters (custom lengths available)
      Tensile Strength>600 N/mm² (for steel core)
      Bonding Strength>500 N/mm² (ensures permanent molecular bond)
      ResistanceLow electrical resistance for efficient current dissipation
      Tip DesignSharpened / Pointed for optimal lightning strike interception
      ComplianceUL 467, IEC 62561-2, IEEE, NFPA 780, BS EN 50522
      PackagingSecurely packaged to prevent damage during transit

      Why Choose Our Copper Bonded Lightning Arrestor Rods?

      We are committed to delivering superior quality and unwavering reliability. Our copper bonded rods undergo stringent quality control processes to ensure every product meets the highest performance and safety standards. With our expertise and dedication to innovation, you can trust that you are investing in a lightning protection solution that will perform exceptionally for years to come.

      Installation Guidance

      Our Copper Bonded Lightning Arrestor Rods are designed to be installed vertically at the highest point of a structure or at strategic locations as part of a complete lightning protection system (LPS). They should be properly connected to a robust grounding electrode system using appropriate conductors and clamps. Professional installation by certified lightning protection specialists is highly recommended to ensure optimal performance and compliance with local and international safety codes.

      Ordering Information & Call to Action

      Protect your assets today with the proven reliability of our Copper Bonded Lightning Arrestor Rods.

      Contact us now to discuss your specific project requirements, request a detailed quote, or place an order. Our team of experts is ready to assist you in designing the perfect lightning protection solution.

      Note: Specifications are subject to change without prior notice as part of continuous product improvement. Please confirm current specifications at the time of order.

      Tags: Copper Bonded Lightning Arrestor Rod